Marey Gas Models Manuel d'instructions Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 7
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
temperature is around or below freezing (32 degrees F, 0 degrees C). Unhook the
outgoing water line to ensure that any water in the heat exchanger cause is
drained. The lack of proper drainage in your unit may cause damage to the water
heaterthat will not be repairable. See our warranty policy.
The temperature of the incoming water with the amount of heat applied are
influential in the temperature of the outgoing water.
1. Set the gas regulator to low, and the water regulator to high, feel the outgoing
water. This is the lowest setting available.
2. To raise the outgoing temperature, turn the gas valve towards maximum. There
will be a slight delay between increasing the gas supply and the increase in water
3. If you wish to use water without it being heated turn the ON/OFF switch at the
bottom of the unit to “OFF” (“0”). This will disconnect the gas flow and igniters.
temperature. If you want the highest setting available then turn water regulator all
the way to the maximum. Adjust slowly and check the temperature often.
The unit will produce temperatures capable of harming the skin! Make sure
that you test the water before taking a shower!
The units does not start at all
1. Make sure you have new batteries installed in the correct position. Check the cap
of the battery case for instructions on how they should be installed.
2. Usually, the main reason most units does not ignite is that there is not enough
water pressure. The unit must have a have a minimum of 5 PSI of sustained water
pressure to turn on.
3. Verify that the water hoses are connected properly, if they are not the unit will not
work. Check that the incoming is on the far right and the outgoing is in the middle.
4. The "On/Off" switch should be with the “—“ sign pushed down.
ADJUSTMENT: On the bottom of the unit, you will see 2 oval holes in the case.
The furthest hole on the right looks up at the water regulator where you will see two
Philip head screws. Furthest on the right the is a screw that you must turn about a
¼ or ½. The unit will be able to operate on a lower water pressure by restricting the
flow.
5. During shipping if a wire disconnected, make sure that the gas valve and the
switch is shut off. The front cover is held by four screws, two at the top and two at the
bottom. The knobs pull off. All the wiring is done with push together plastic
connectors. When a further dismantling of the unit they are all visible.
6. There is a possibility that some epoxy or debris might have entered the water
regulator. Check that the water inlet filter screen is clear of debris. To flush the
system you can reverse the hookup by taking the water source and hooking it up to
the water outlet side and back.
If the gas cylinder is contaminated by air, cycle the unit on and off several times to
purge the air from the gas.
0908
Hot
water out
Cold
water in
LPG (Liquid Propane Gas)
GA5PORT
2.2 LPM / 0.58 GPM
5 LPM / 1.4 GPM
35,000 BTU/h
0.4 PSI
3.6 - 145.0 PSI
Electric Pulse, D Cell Battery Powered
(No electrical connection required)
Auto-cutt-off, water, controlled, automatic
ignition, anti-dry combustion, over-pressure,
overheating, flameout protection
17.0" x 11.4" x 4.7"
12 lbs
½" NPT, incoming/outgoing water & gas
54 - 87%
TECHNICAL SPECIFICATIONS - PORTABLE
Fuel Type
Model
Activation Flow Rate
Maximmum Flow Rate
BTU/h
Related Gas Pressure
Aplicable Water Pressure
Ignition
Protections
Height x Width x Depth
Weight
Pipe Fittings
Energy Efficiency
Vue de la page 4
1 2 3 4 5 6 7

Commentaires sur ces manuels

Pas de commentaire